50 FK
Facade 50 FK is a system for the construction of continuous or structural, self-supporting, fully glazed, warm-insulated facade construction of aluminum profiles. Specially designed facade window openings with swivel-hinge, inward or outward hinge, parallel opening and roof windows can be used for opening areas. FEAL systems for windows and doors are also compatible with the facade. The glazing of the continuous facade is performed with the help of EPDM seals and clamping and cover moldings. Cover clamps are placed on the clamping strips, which can be of different shapes (square, shallow or deep, rounded, elliptical) and depth. Exceptions are moldings which, due to their specific shape, are both clamping and cover moldings. The glazing of the structural facade is performed with the help of EPDM seals, glass holders and silicone sealant of structural glass. As materials of facade components, materials resistant to weather conditions, temperature differences, mold, and waterproof protective tapes that prevent the penetration of water and moisture into the insulation are used. The FEAL 50 FK facade system allows conduction of condensate in two or three levels, i.e. flats. All vertical and horizontal profiles have grooves for condensate conduction and their mutual connections are made so that these grooves overlap. At the same time, the air flows through the verticals and horizontals from the parapet to the attic, whereby the necessary ventilation of the facade is achieved and the moisture created by condensation dries.
Technical characteristics of the system:
- depth of the vertical: 90, 120, 140, 160, 200, 270 mm
- depth of the horizontal: 88, 118, 138, 158, 198 268 mm
- depth of the auxiliary horizontal: 88, 118, 138, 158 mm
- visible profile width: 50 mm
- depth of the filling: 4 - 56 mm
- air-permeability: EN 12207 (class 4)
- watertightness: EN 12154 (class R7)
- resistance to wind gusts: EN 12210 (class C5/B5)
- noise protection: EN ISO 717-1 (Rw=43 dB)
- antiburglary EN 1627 (RC2)
- Uw coefficient calculation: DIN EN ISO 10077-2 (≥0,72 Wm²/K)
- basic material: EN AW-6060
- sealing material: EPDM
- surface treatment: DIN 17611
- quality control: DIN EN ISO 9001